CVE-2026-105105

Crítico
9.8
0.05.010.0
Ano
2026
Publicado
3 de out de 2026
Dispositivos afetados
0
Pontuação CVSS
9.8

O que é CVE-2026-105105?

CWE-306: Missing Authentication for Critical Function in the ait.core.server telemetry and command broker (ait-server) in NASA-AMMOS AIT-Core through 3.1.1 allows an unauthenticated remote attacker with network access to the ZeroMQ message bus to inject spacecraft command data, exfiltrate command and telemetry traffic, inject forged telemetry, or disrupt the command and telemetry bus. The ait-server ZeroMQ broker binds its XSUB and XPUB sockets to all network interfaces by default without authentication or transport security. An attacker able to reach TCP port 5559 can publish messages onto internal topics, including the __commands__ command topic. With the shipped default configuration, command messages are forwarded through command_stream and emitted on the command-uplink UDP path. An attacker able to reach TCP port 5560 can subscribe to command and telemetry traffic on the ground bus. AIT-Core 3.1.2 changes the default ZeroMQ bind addresses to loopback.

CVSS Vector Breakdown

CVSS 3.1
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
AV
Attack Vector
Network

Exploitable remotely over the network without requiring access to the local system.

AC
Attack Complexity
Low

No special conditions required. Exploit can be performed reliably and repeatedly.

PR
Privileges Required
None

No authentication required. Any anonymous user can exploit this vulnerability.

UI
User Interaction
None

No user interaction required. Exploit runs without any victim action.

S
Scope
Unchanged

Exploiting the vulnerability only affects the vulnerable component itself.

C
Confidentiality Impact
High

Complete loss of confidentiality. All data on the component may be exposed.

I
Integrity Impact
High

Complete loss of integrity. Attacker can modify any file or data on the component.

A
Availability Impact
High

Complete denial of service. The component becomes fully unavailable.

Perguntas frequentes

Qual é a gravidade de CVE-2026-105105?

CVE-2026-105105 tem uma pontuação CVSS de 9.8/10, classificada como Critical. Este é o nível de gravidade mais alto — a aplicação imediata do patch é fortemente recomendada.

O que significa a pontuação CVSS para CVE-2026-105105?

O CVSS (Common Vulnerability Scoring System) avalia a gravidade das vulnerabilidades de 0,0 a 10,0. CVE-2026-105105 pontua 9.8/10 (Critical). Pontuações de 9,0–10,0 são Críticas, 7,0–8,9 Altas, 4,0–6,9 Médias e abaixo de 4,0 Baixas.

Quais dispositivos são afetados por CVE-2026-105105?

A lista de dispositivos confirmados como afetados por CVE-2026-105105 é mostrada na seção "Dispositivos afetados" acima. Compare sua versão de firmware com o aviso de segurança do fornecedor e aplique o último patch.

Como corrijo ou mitigo CVE-2026-105105?

Aplique a última atualização de firmware ou software do fornecedor. Consulte a seção de Referências acima para avisos oficiais e notas de patch. Se nenhum patch estiver disponível, considere desativar o recurso afetado ou isolar o dispositivo de redes não confiáveis.