CVE-2026-15267
Medio¿Qué es CVE-2026-15267?
The Taskbuilder – Project Management & Task Management Tool With Kanban Board plugin for WordPress is vulnerable to SQL Injection via the 'wppm_proj_filter' parameter in versions up to, and including, 5.0.9. This is due to insufficient escaping on the user-supplied parameter and the lack of sufficient preparation on the existing SQL query — the value is re-read at line 144 using only sanitize_text_field() (overwriting the earlier absint() result), then concatenated into the SQL WHERE clause as an unquoted numeric operand using only esc_sql(), which does not protect against injection in that context, and finally string-interpolated into the $wpdb->prepare() format string, bypassing parameterization entirely. This makes it possible for authenticated attackers, with subscriber-level access and above, to append additional SQL queries into already existing queries that can be used to extract sensitive information from the database.
CVSS Vector Breakdown
CVSS 3.1Exploitable remotely over the network without requiring access to the local system.
No special conditions required. Exploit can be performed reliably and repeatedly.
Basic user account required (e.g. standard login without admin rights).
No user interaction required. Exploit runs without any victim action.
Exploiting the vulnerability only affects the vulnerable component itself.
Complete loss of confidentiality. All data on the component may be exposed.
No integrity impact. Data cannot be modified.
No availability impact. Service remains fully operational.
Preguntas frecuentes
CVE-2026-15267 tiene una puntuación CVSS de 6.5/10, clasificada como Medium. Revise la lista de productos afectados y aplique los parches del fabricante.
El CVSS (Common Vulnerability Scoring System) califica la gravedad de las vulnerabilidades de 0,0 a 10,0. CVE-2026-15267 obtiene 6.5/10 (Medium). Las puntuaciones de 9,0–10,0 son Críticas, 7,0–8,9 Altas, 4,0–6,9 Medias y por debajo de 4,0 Bajas.
La lista de dispositivos confirmados como afectados por CVE-2026-15267 se muestra en la sección "Dispositivos afectados" arriba. Compare su versión de firmware con el aviso de seguridad del proveedor y aplique el último parche.
Aplique la última actualización de firmware o software del proveedor. Consulte la sección de Referencias arriba para ver avisos oficiales y notas de parches. Si no hay parche disponible, considere deshabilitar la función afectada o aislar el dispositivo de redes no confiables.