CVE-2026-37504

Medium
5.3
0.05.010.0
Year
2026
Published
May 1, 2026
Known Affected Devices
0
CVSS Score
5.3

What is CVE-2026-37504?

Sensitive server_token exposed via GET parameter in V2Board thru 1.7.4. In app/Http/Controllers/Server/UniProxyController.php, the server authentication token is accepted via GET parameter transmission. The token appears in URLs such as /api/v1/server/UniProxy/user?token=SECRET, causing it to be recorded in web server access logs, browser history, HTTP Referer headers, and proxy/CDN logs. An attacker who gains access to any log source can extract the token and impersonate a proxy server node, potentially intercepting all user traffic.

CVSS Vector Breakdown

CVSS 3.1
CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N
AV
Attack Vector
Network

Exploitable remotely over the network without requiring access to the local system.

AC
Attack Complexity
High

Exploit requires specific conditions, timing, or configuration to succeed.

PR
Privileges Required
None

No authentication required. Any anonymous user can exploit this vulnerability.

UI
User Interaction
Required

Victim must take an action (e.g. click a link, open a file) for the exploit to succeed.

S
Scope
Unchanged

Exploiting the vulnerability only affects the vulnerable component itself.

C
Confidentiality Impact
High

Complete loss of confidentiality. All data on the component may be exposed.

I
Integrity Impact
None

No integrity impact. Data cannot be modified.

A
Availability Impact
None

No availability impact. Service remains fully operational.

FAQ

How severe is CVE-2026-37504?

CVE-2026-37504 has a CVSS score of 5.3/10, rated as Medium. Review the affected products list and apply vendor patches.

What does the CVSS score mean for CVE-2026-37504?

CVSS (Common Vulnerability Scoring System) rates vulnerability severity from 0.0 to 10.0. CVE-2026-37504 scores 5.3/10 (Medium). Scores 9.0–10.0 are Critical, 7.0–8.9 are High, 4.0–6.9 are Medium, and below 4.0 are Low.

Which devices are affected by CVE-2026-37504?

The list of devices confirmed to be affected by CVE-2026-37504 is shown in the "Affected Devices" section above. Check your firmware version against the vendor security advisory and apply the latest patch.

How do I fix or mitigate CVE-2026-37504?

Apply the latest firmware or software update from the vendor. Check the References section above for official advisories and patch notes. If no patch is available, consider disabling the affected feature or isolating the device from untrusted networks.