CVE-2026-124558

High
7.3
0.05.010.0
Year
2026
Published
Nov 9, 2026
Known Affected Devices
0
CVSS Score
7.3

What is CVE-2026-124558?

A vulnerability has been found in DataLinkDC Dinky up to 1.2.5. The impacted element is the function SqlGateway.onOpen of the file SqlGateway.java of the component sql-gateway Endpoint. Such manipulation of the argument connectAddress leads to server-side request forgery. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The researcher claims to have submitted a GHSA on the repository of the project.

CVSS Vector Breakdown

CVSS 3.1
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
AV
Attack Vector
Network

Exploitable remotely over the network without requiring access to the local system.

AC
Attack Complexity
Low

No special conditions required. Exploit can be performed reliably and repeatedly.

PR
Privileges Required
None

No authentication required. Any anonymous user can exploit this vulnerability.

UI
User Interaction
None

No user interaction required. Exploit runs without any victim action.

S
Scope
Unchanged

Exploiting the vulnerability only affects the vulnerable component itself.

C
Confidentiality Impact
Low

Some sensitive information is disclosed, but attacker has limited access.

I
Integrity Impact
Low

Attacker can modify some data, but scope or consequence is limited.

A
Availability Impact
Low

Reduced performance or intermittent outages, but service remains available.

FAQ

How severe is CVE-2026-124558?

CVE-2026-124558 has a CVSS score of 7.3/10, rated as High. This is a high severity vulnerability and should be patched as soon as possible.

What does the CVSS score mean for CVE-2026-124558?

CVSS (Common Vulnerability Scoring System) rates vulnerability severity from 0.0 to 10.0. CVE-2026-124558 scores 7.3/10 (High). Scores 9.0–10.0 are Critical, 7.0–8.9 are High, 4.0–6.9 are Medium, and below 4.0 are Low.

Which devices are affected by CVE-2026-124558?

The list of devices confirmed to be affected by CVE-2026-124558 is shown in the "Affected Devices" section above. Check your firmware version against the vendor security advisory and apply the latest patch.

How do I fix or mitigate CVE-2026-124558?

Apply the latest firmware or software update from the vendor. Check the References section above for official advisories and patch notes. If no patch is available, consider disabling the affected feature or isolating the device from untrusted networks.