CVE-2026-123033
HighWhat is CVE-2026-123033?
Authentication bypass in the HA heartbeat origin check in middlewared in TrueNAS SCALE before 25.10.8 (and in release trains before their respective fixes) allows an attacker on the same network segment to achieve unauthenticated full-administrator API access and execute commands as root. middlewared registers the HA peer-authentication hook (ha_permission) unconditionally, with no failover-licence or heartbeat-interface check. An unauthenticated connection whose TCP peer address is a hardcoded HA heartbeat address (169.254.10.1 or 169.254.10.2) and whose peer port is <= 1024 is granted a node credential that is authorized for every API method and treated as full administrator. Both conditions are properties of the attacker's own socket, and thus an attacker on the same layer-2 segment satisfies them without forging anything. The hook is present on non-HA, unlicensed, single-node Community Edition installations. The fix additionally requires that the connection terminate on the HA heartbeat listener (a local address/port the attacker cannot control).
CVSS Vector Breakdown
CVSS 3.1Exploitable from an adjacent network (e.g. same LAN, Wi-Fi segment, Bluetooth).
Exploit requires specific conditions, timing, or configuration to succeed.
No authentication required. Any anonymous user can exploit this vulnerability.
No user interaction required. Exploit runs without any victim action.
Exploiting the vulnerability can affect other components beyond the vulnerable one.
Complete loss of confidentiality. All data on the component may be exposed.
Complete loss of integrity. Attacker can modify any file or data on the component.
Complete denial of service. The component becomes fully unavailable.
FAQ
CVE-2026-123033 has a CVSS score of 8.3/10, rated as High. This is a high severity vulnerability and should be patched as soon as possible.
CVSS (Common Vulnerability Scoring System) rates vulnerability severity from 0.0 to 10.0. CVE-2026-123033 scores 8.3/10 (High). Scores 9.0–10.0 are Critical, 7.0–8.9 are High, 4.0–6.9 are Medium, and below 4.0 are Low.
The list of devices confirmed to be affected by CVE-2026-123033 is shown in the "Affected Devices" section above. Check your firmware version against the vendor security advisory and apply the latest patch.
Apply the latest firmware or software update from the vendor. Check the References section above for official advisories and patch notes. If no patch is available, consider disabling the affected feature or isolating the device from untrusted networks.