CVE-2024-47607

Critical
9.8
0.05.010.0
Year
2024
Published
Dec 12, 2024
Known Affected Devices
0
CVSS Score
9.8

What is CVE-2024-47607?

GStreamer is a library for constructing graphs of media-handling components. stack-buffer overflow has been detected in the gst_opus_dec_parse_header function within `gstopusdec.c'. The pos array is a stack-allocated buffer of size 64. If n_channels exceeds 64, the for loop will write beyond the boundaries of the pos array. The value written will always be GST_AUDIO_CHANNEL_POSITION_NONE. This bug allows to overwrite the EIP address allocated in the stack. This vulnerability is fixed in 1.24.10.

CVSS Vector Breakdown

CVSS 3.1
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
AV
Attack Vector
Network

Exploitable remotely over the network without requiring access to the local system.

AC
Attack Complexity
Low

No special conditions required. Exploit can be performed reliably and repeatedly.

PR
Privileges Required
None

No authentication required. Any anonymous user can exploit this vulnerability.

UI
User Interaction
None

No user interaction required. Exploit runs without any victim action.

S
Scope
Unchanged

Exploiting the vulnerability only affects the vulnerable component itself.

C
Confidentiality Impact
High

Complete loss of confidentiality. All data on the component may be exposed.

I
Integrity Impact
High

Complete loss of integrity. Attacker can modify any file or data on the component.

A
Availability Impact
High

Complete denial of service. The component becomes fully unavailable.

Known Affected Devices

FAQ

How severe is CVE-2024-47607?

CVE-2024-47607 has a CVSS score of 9.8/10, rated as Critical. This is the highest severity level - immediate patching is strongly recommended.

What does the CVSS score mean for CVE-2024-47607?

CVSS (Common Vulnerability Scoring System) rates vulnerability severity from 0.0 to 10.0. CVE-2024-47607 scores 9.8/10 (Critical). Scores 9.0–10.0 are Critical, 7.0–8.9 are High, 4.0–6.9 are Medium, and below 4.0 are Low.

Which devices are affected by CVE-2024-47607?

The list of devices confirmed to be affected by CVE-2024-47607 is shown in the "Affected Devices" section above. Check your firmware version against the vendor security advisory and apply the latest patch.

How do I fix or mitigate CVE-2024-47607?

Apply the latest firmware or software update from the vendor. Check the References section above for official advisories and patch notes. If no patch is available, consider disabling the affected feature or isolating the device from untrusted networks.