CVE-2024-47602

High
7.5
0.05.010.0
Year
2024
Published
Dec 12, 2024
Known Affected Devices
0
CVSS Score
7.5

What is CVE-2024-47602?

GStreamer is a library for constructing graphs of media-handling components. A null pointer dereference vulnerability has been discovered in the gst_matroska_demux_add_wvpk_header function within matroska-demux.c. This function does not properly check the validity of the stream->codec_priv pointer in the following code. If stream->codec_priv is NULL, the call to GST_READ_UINT16_LE will attempt to dereference a null pointer, leading to a crash of the application. This vulnerability is fixed in 1.24.10.

CVSS Vector Breakdown

CVSS 3.1
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
AV
Attack Vector
Network

Exploitable remotely over the network without requiring access to the local system.

AC
Attack Complexity
Low

No special conditions required. Exploit can be performed reliably and repeatedly.

PR
Privileges Required
None

No authentication required. Any anonymous user can exploit this vulnerability.

UI
User Interaction
None

No user interaction required. Exploit runs without any victim action.

S
Scope
Unchanged

Exploiting the vulnerability only affects the vulnerable component itself.

C
Confidentiality Impact
None

No confidentiality impact. Sensitive data is not exposed.

I
Integrity Impact
None

No integrity impact. Data cannot be modified.

A
Availability Impact
High

Complete denial of service. The component becomes fully unavailable.

Known Affected Devices

FAQ

How severe is CVE-2024-47602?

CVE-2024-47602 has a CVSS score of 7.5/10, rated as High. This is a high severity vulnerability and should be patched as soon as possible.

What does the CVSS score mean for CVE-2024-47602?

CVSS (Common Vulnerability Scoring System) rates vulnerability severity from 0.0 to 10.0. CVE-2024-47602 scores 7.5/10 (High). Scores 9.0–10.0 are Critical, 7.0–8.9 are High, 4.0–6.9 are Medium, and below 4.0 are Low.

Which devices are affected by CVE-2024-47602?

The list of devices confirmed to be affected by CVE-2024-47602 is shown in the "Affected Devices" section above. Check your firmware version against the vendor security advisory and apply the latest patch.

How do I fix or mitigate CVE-2024-47602?

Apply the latest firmware or software update from the vendor. Check the References section above for official advisories and patch notes. If no patch is available, consider disabling the affected feature or isolating the device from untrusted networks.